Clean agent
Clean agents (clean fire extinguishing agents or gaseous fire suppressants) take the form of inert gases that were developed as an environmentally acceptable alternative to halon which is banned in the UK. The gaseous fire suppressant is stored as a pressurised liquid which when discharged into the air turns immediately to gas and can smother a fire. However, some types also discharge as a rapidly evaporating liquid.
These fire suppressants are typically non-corrosive, do not usually damage delicate equipment that is away from the fire and do not usually leave a residue. They work by blocking the combustion reaction while it is occurring.
For these reasons, clean agents are effective on electrical fires; they offer a further benefit in that, unlike water and other liquids, they are formulated to not conduct electricity back to the operator. They are therefore used in wide-bodied commercial aircraft, pharmaceutical and industrial plants, computer rooms, clean rooms, switch rooms, data storage, telecoms areas and art storage areas, to name but a few.
A clean agent suppressant system typically consists of the agent, the container it is stored in, agent release valves, fire detectors, fire detection system (wiring control panel, actuation signalling) and the means to convey the agent to the fire – the piping and dispersion nozzles. Also possible, although less common, is delivering the agent using a solid propellant gas generator that produces either inert or chemically active gas.
Clean agent fire suppressants may be effective in fighting the following European fire classifications:
- Class A: Combustible materials (wood, paper, fabric, most kinds of refuse);
- Class B: Flammable liquids;
- Class C: Flammable gases.
Clean agent fire suppressants can also come in traditional hand-held portable cylinder fire extinguishers, with an activation trigger and nozzle. Or, they may be ceiling-mounted circular discs of 4-10kg capacities with automatic fire detection and activation. Being ceiling mounted they are designed to have a better reach than normal fire extinguishers and are useful in areas where the chances of early fire detection are low. This includes areas where there is little human traffic flow e.g in factories with large storage areas, server rooms and areas such as high chemical stacks that are beyond the range of normal fire extinguishers. A downside is that the red ‘bulb-shaped’ containers can look unsightly although this may not be considered problematic in an industrial setting.
[edit] Halon
In the past, many systems used halon as the base extinguishing agent, considered then as being an ‘environment friendly’ fire extinguishing chemical which produced a halogenated effect. In particular, a variant called HCFC 123 used in some systems was introduced in the 1990s to replace ozone-depleting agents such as Halon 1211 and BCFs.
HCFC 123 was at one time regarded as one of the ‘cleanest’ and ‘most powerful’ extinguishing agents available. According to Gov.UK. HCFC 123 (C2HF3Cl2 Dichlorotrifluoroethane) has an ozone-depleting potential of 0.02. This can be compared to say, HBFC-234 which has an ODP of 7.5. However, HCFC 123 was considered as having very few risks and a relatively small amount was needed to extinguish the fire.
[edit] Related articles on Designing Buildings Wiki
- Automatic fire sprinkler systems: A good practice guide.
- Costs of water automatic sprinkler systems.
- Design benefits of automatic sprinkler systems granted under approved document B.
- Drenchers.
- Fire detection and alarm system.
- Fire detector.
- Fire in buildings.
- Fire protection engineering.
- Fire retardant.
- Fire safety design.
- Sprinkler systems explained: A guide to sprinkler installation standards and rules.
- The cost efficiency of different combinations of fire protection measures.
- The impact of automatic sprinklers on building design.
Featured articles and news
A safe energy transition – ECA launches a new Charter
Practical policy actions to speed up low carbon adoption while maintaining installation safety and competency.
Frank Duffy: Researcher and Practitioner
Reflections on achievements and relevance to the wider research and practice communities.
The 2026 Compliance Landscape: Fire doors
Why 'Business as Usual' is a Liability.
Cutting construction carbon footprint by caring for soil
Is construction neglecting one of the planet’s most powerful carbon stores and one of our greatest natural climate allies.
ARCHITECTURE: How's it progressing?
Archiblogger posing questions of a historical and contextual nature.
The roofscape of Hampstead Garden Suburb
Residents, architects and roofers need to understand detailing.
Homes, landlords. tenants and the new housing standards
What will it all mean?
The Architectural Technology podcast: Where it's AT
Catch-up on the latest episodes.
Edmundson Apprentice of the Year award 2026
Entries now open for this Electrical Contractors' Association award.
Traditional blue-grey slate from one of the oldest and largest UK slate quarries down in Cornwall.
There are plenty of sources with the potential to be redeveloped.
Change of use legislation breaths new life into buildings
A run down on Class MA of the General Permitted Development Order.
Solar generation in the historic environment
Success requires understanding each site in detail.
Level 6 Design, Construction and Management BSc
CIOB launches first-ever degree programme to develop the next generation of construction leaders.
Open for business as of April, with its 2026 prospectus and new pipeline of housing schemes.
The operational value of workforce health
Keeping projects moving. Incorporating unplanned absence and the importance of health, in operations.